Abstract

A numerical model was proposed to analyze the heat and mass transfer process of wood during the entire period of fire including heating and cooling periods. Conservation of enthalpy and mass were considered. Velocities of gas and liquid were calculated by Darcy’s law. The desorption and adsorption of liquid water, pyrolysis of volatile components, burning of combustible pyrolysis gas and glowing of char were considered. Shrinkage of solid and subsequent surface cracking were included in this model. The effect of increasing heat and mass transfer by crack were expressed by additional heat and mass fluxes. Temperature dependent physical properties were used. To verify the model, simulation was conducted and compared with results measured in fire resistance test of glue laminated timber (GLT) wall reported in reference. Temperature, moisture content and burnt-out/charring/coloring depth were compared with experimental results. Experimental and numerical results on temperature and moisture content are in good agreement during the entire experiment process, including heating and cooling period. Numerical result on charred front also in a reasonable agreement with measured value, but the colored depth was smaller than experimental value.

1. Introduction

Special attention should be paid to the fire safety of timber buildings because of the flammability of wood. Failure of structural elements should be avoided in the whole process of fire including cooling period, to ensure the safety of evacuation and firefighting[1]. A widely used method to evaluate the fire safety of timber structural material is fire resistance test. In these tests, structural material was heated in a furnace with standard fire temperature curves such as ISO 834[2] for a prescribed heating duration. Many researchers have conducted standard fire tests to examine the fire resistance of wood[1,3,4].
However, the cost of conducting experiments is very high. The need for predicting fire resistance by computer simulation is obvious. For that purpose, it is necessary to build a numerical model which can reproduce and analyze the behavior of wood under fire heating. The simplest approach of modelling is to use the transient heat conduction equation, with a heat source term representing heat generation and absorption. This type of method is widely used due to its simplicity. For example, Darmon et al.[5] calculated the behavior of cross laminated timber (CLT) beam under ISO834 standard fire using 2D heat transfer equation. Khelifa et al.[6] analyzed the behavior of dowel timber, with structural analysis combined with the heat conduction model. Konig[7] calculated the temperature inside timber wall under fire heating.
Another approach is to consider simultaneous heat and mass transfer. This type of approach is necessary when detailed analysis is required, since transportation of water vapor, liquid water, pyrolysis gas and oxygen will affect the conditions of heat generation and burning intensity. Pecenko[8] proposed a 2D numerical model to calculate the heat and moisture transfer for wood exposed to fire. Suzuki[9] also proposed a model to calculate the heat and moisture transfer inside wood. Model proposed by Fredlund[10] considered the mass transfer of air, water vapor and pyrolysis gas. An equilibrium approach was used to calculate the rate of phase change of water, assuming that the water vapor pressure is equal to saturate pressure. Bryden et al.[11] proposed a model to simulate the behavior of wood under high temperature heating. Pyrolysis was simulated as a two-step reaction with 3 primary reactions in the first step and 2 secondary reactions in the second step. Besides the heat transfer process, the transportation of water vapor, pyrolysis gas and tar were considered in their model.
Although previous researchers have reported many works on modelling of wood burning, there are still some problems that exist while using these models to analysis fire resistance of wood. Most of the models proposed in previous research have ignored some important physical phenomena like glowing combustion, shrinkage and crack formation. These phenomena will greatly influence the behavior of wood during the cooling process. For example, significant amounts of heat will be generated by glowing combustion[12]. Additional heat and mass flux will flow into the specimen directly via surface cracking, causing the rapid temperature rise.
In this paper, a numerical model which can simulate the combustion progress of wood was proposed to be applicable to entire process of fire including heating and cooling period. Both heat and mass transfer were considered in this model. Transfer of five species of gases were calculated separately, including water vapor, pyrolysis gas, oxygen, nitrogen, and carbon dioxide. Change on grid size and surface cracking was included. The model was verified by conducting simulation based on conditions of a fire resistance test. Temperature, moisture content, and charring depth were compared with experimental results.

2. Model Description

2.1 General information

This model considers wood under fire heating as a combination of solid, liquid and gas. Solid phase consists of volatile components and non-volatile components. Liquid phase consists of liquid water. Gas phase consists of various types of gases, including water vapor, combustible pyrolysis gas, nitrogen, oxygen, and carbon dioxide. While calculating the conservation of liquid and gases, mass transfer and reactions were taken into consideration.
Three types of reactions were considered in this model, including pyrolysis of volatile component, the burning of pyrolysis gas, and glowing combustion of non-volatile components (char). During pyrolysis, volatile components are decomposed to pyrolysis gas. For glowing combustion of non-volatile components, non-volatile components and oxygen were consumed, and carbon dioxide was generated. The burning of pyrolysis gas was assumed to occur on the heating surface, the crack and inside of the wood. This reaction consumes pyrolysis gas and oxygen, generates carbon dioxide and water vapor. Transform between liquid water and water vapor, including adsorption of water vapor and desorption of liquid water were also considered. Shape changes of the specimen, including change on sample length and surface cracking, was included in this model. For numerical simplicity, this model was created in one dimension.

2.2 Governing equations

2.2.1 General conservation equation

The equation of mass and enthalpy conservation were basically established by using the following general conservation equation as in Eq. (1).
(1)
∂ρ˜ϕ∂t+∂∂xɛ(ρ˜vϕ-D∂ϕ∂x)+∂∂x(ϕ˜crack)=ɛS

2.2.2 Mass and species conservation

The mass conservation equations of solid, liquid, total gas and each species of gas are expressed by Eqs. (2)-(5). Subscript denotes the index representing each component in solid or gas.
(2)
∂ ρ˜sol, i∂ t=ɛSsol,i
(3)
∂ ρ˜liq∂ t+∂∂ xɛ(ρ˜liqvliq-Dliq∂ ρ˜liq∂ x)=ɛSliq
(4)
∂ ρ˜gas∂ t+∂∂ xɛ(ρ˜gasvgas)=ɛ∑Sgas,i
(5)
∂ρ˜gasYgas,i∂ t+∂∂ x(ρ˜gasYgas,ivgas-ρ˜gasDi∂ Ygas,i∂ x)+∂∂ x(mcrack,i)=ɛSgas,i

2.2.3 Enthalpy conservation

The enthalpy conservation equation is shown by Eq. (6), while using temperature as variable.
(6)
∂∑sol, liq,gas(ρ˜c)T∂t+∂∂xɛ[(ρ˜liqcliqvliq+∑gas(ρ˜ici)vgas)T-ksol∂T∂x]+∂∂x(qcrack,in)=ɛ[Qads+Qpyro+Qglow+Qflam]

2.2.4 Velocity related equations

Velocity of gas and liquid were calculated using Darcy’s Law.
(7)
vgas=-xgasμgas∂ P∂ x
(8)
vliq=-xliqμliq∂ (P-12400α*(ρ˜liq1000τ)-0:61)∂ x
The second term in the partial derivative term of Eq. (8) is the capillary pressure of wood, calculated by an equation proposed by Spolek[13]. At here, a correlation factor a was added to Spolek’s equation, represents that the capillary pressure becomes zero when temperature is above 100 ℃.
(9)
α={1         (T≤293.15)-180(T-293.15)+1         (293.15<T<373.15)0         (373.15≤T)
Since it is necessary to use pore pressure to calculate velocity, an equation to calculate pore pressure directly was used. A diffusion equation on pressure, Eq. (10), was derived based on Eqs. (4), (5), Ideal gas law, and Dalton’s law of partial pressure, referring to Fredlund’s approach[10].
(10)
τgasRT∂ P∂ t=∂∂ x((∑ρ˜iMi)ɛxgasμgas∂ P∂ x)+τgasRT2∂ T∂ tP+ɛ∑SiMi
After pressure was calculated by Eq. (10), the mass of gas contained per unit volume of wood ρ~gas, was calculated by Eq. (11).
(11)
ρ˜gas=∑MiYi∑YiτgasPRT

2.3 Shape change of specimen

2.3.1 Change on grid length by shrinkage and burnt-out

Length changes due to shrinkage and burnt-out are expressed by Eq. (12). Shrinkage was expressed using Davidsson’s equation[14], while burnt-out were expressed by linear interpolation. r and r∞ represent the residual ratio at current state and completely pyrolyzed state, respectively. During simulation, grid shrinkage occurs from heating surface towards non-heating surface in one direction.
(12)
dxdxini={1-η(1-r)2         (r∞≤r≤1)0.001+r-0.01r∞-0.01(0.999-η(1-r∞)2)         (0.01≤r<r∞)0.001         (r≤0.01)

2.3.2 Surface crack

Figure 1(a) expresses the image of a specimen with surface crack. The specimen is with dimensions of length L1, width L2, and height L3. Cracks were set as a series of triangular slots that run through the entire specimen along the L1 direction. Three cracks are drawn in Figure 1(a), but this is just a schematic example and does not mean that there are only three cracks in all simulations. The depth of the crack is L4, and cracks distribute at equal interval L5. Figure 1(b) expresses the position of grid number j in a single crack. The symbol L1 denotes the distance from surface to grid j. It should be pointed out that the simulation model proposed in this paper is a 1D model. The heat and mass exchange between external environment and specimen via all cracks on the L1L2 surface will be expressed in the form of heat flow and gas flow in L3 direction.
The shape and interval of the cracks does not change over time, but the depth and width of crack are increased as the residual ratio r is decreased. Mechanical deformation was not included. The critical cracking point was set at r=0.95, when cracks were formed after pyrolysis had been slightly progressed. In simulation, the crack depth is first calculated by the residual ratio mentioned above, and then other information about the crack can be calculated by using the predetermined width/depth ratio.
Eq. (13) expresses the equation of additional heat flux into a specific grid inside the specimen, grid j, via crack. The additional heat flow entering the specimen through surface crack consists of three kinds of components, including convective heat flow, radiative heat flow from surrounding gas, and the heat flow due to feedback from flame due to the combustion of pyrolysis gas. Additional heat flux was expressed in the form of boundary condition since grids with crack also interact with outside air like the heated surface.
(13)
qcrack,j,in=δj(Hj(Tair-Tj)+0.95xj˜σ(Tair4-Tj4)+qflam,front)
At here, the convective heat transfer coefficient inside the Hj was assumed to decrease linearly from the value at surface to the minimum value. The value at the bottom of the crack is 0.1 times the value at the surface. The ratio of the surface area δ can be expressed by Eq. (14). This formula can be derived easily using geometry.
(14)
δj={2dxjL51+14β2         (Lj≥L4)0         (Lj≥L4)
The additional mass flux of gas species i can be expressed by Eq. (15).
(15)
mi,j,crack=δjHm,jτgas,jρgas(Yi,j-Yi,air)
As for pressure diffusion equation, the pressures at these grids were set to be equal to the outside air pressure since the grids with cracks can directly contact the outside air.

2.3.3 Ratio of remaining heated surface area

The ratio of remaining heating surface area after crack formation to total area of heating surface at grid no. j can be calculated from Eq. (16).
(16)
ɛj={1-L4-LjβL5         (L4≠0   and   Lj≤L4)1         (other)

2.4 Physical changes and chemical reactions

2.4.1 Adsorption and desorption of water

Rate of water adsorption was expressed by Eq. (17). This equation combined with the approach to express the rate of adsorption (or desorption) is proportional to the difference of actual water vapor pressure and equilibrium vapor pressure, and moisture content[15]. The coefficient b was calibrated by using experimental data measured by Kimura et al.[16]. The calibrated value is b=5.14 x 10-8.
(17)
θads=bρ˜liq(PH2Og-Pequ,   H2Og)

2.4.2 Pyrolysis of volatile components

Pyrolysis of volatile components was represented by the pyrolysis of three types of pseudo composition of wood, the pseudo cellulose (Cel), pseudo hemicellulose (Hemi), and pseudo lignin (Lig). The reaction equations were shown in Eq. (18). These three pseudo components decompose into combustible pyrolysis gas through a one-step chemical reaction.
(18)
Cel→Gas↑Hemi→Gas↑Lig→Gas↑
The reaction rate of wood pyrolysis was expressed using n-th order reaction equation. The rate of pyrolysis can be expressed by Eq. (19), using a three-component reaction model developed by Sun et al.[17]. The rate of pyrolysis gas generation is also equal to the rate of volatile component consumption. Parameters and constants used in this equation like reaction rate parameters Ai, ni, Ei, mass ratio that is able to be pyrolyzed up to 900 ℃ (final pyrolysis) Fi, were taken from reference[17].
(19)
θpyro=ρdry∑FiAi(1-ai)nie-EiRT

2.4.3 Glowing of non-volatile components

The rate of glowing of non-volatile component was expressed by an Arrhenius type Eq. (20) proposed by Chatani et al.[18]. It was assumed that the rate is proportional to oven dried wood density pdry and ratio of current to initial oxygen mass fraction. The temperature for glowing start Tglow,start and glowing end Tglow,end is 366 ℃ and 166 ℃[12], respectively. The symbol r∞ represents the residual ratio that pyrolysis of the volatile components had completed.
(20)
θglow={0   (r>r∞ and T<Tglow,start)0   (r≤r∞ and T<Tglow,end)ρdryYO2YO2,ini0.0289 exp (-376898.314 T)         (others)

2.4.4 Burning of pyrolysis gas

Burning rate of pyrolysis gas was expressed by Eq. (21). It was assumed that pyrolysis gas burns immediately after generation. Ignition temperature was set as 623K (350 ℃), which is based on the observation in cone calorimeter experiments[19].
(21)
θcomb={YO2YO2,iniθpyro         (if         Tsurf≥623 K)0   (others)
In addition to the burning of pyrolysis gas that occurred inside the grid, there is also a part of pyrolysis gas burned on the external surface of the specimen, or on the surface of the crack. Heat flux due to burning of pyrolysis gas at the surface and inside the crack can be expressed by Eqs. (22) and (23), where half of the heat generation was assumed to come back to the specimen.
(22)
qp,front=12ΔLcombρgasHmτfront(Yp,front-Yp,air)
(23)
qp,crack,j=12xj˜Δ Lcomb∑i=0i=crack bottomρgasHmɛiτi(Yp,i-Yp,air)

2.5 Source terms

It is necessary to use reactions rates mentioned in section 2.4 expressing the source terms, to calculate the governing equations. In this section, the equations of mass-related and enthalpy-related source terms were summarized.

2.5.1 Source terms in mass-related equations

Source terms in mass-related equations include the terms of volatile components Svola, non-volatile components Snonv, liquid water Sliq, water vapor SH20g, pyrolysis gas Sp, oxygen SO2, and carbon dioxide SCO2. These source terms are shown in Eqs. (24)~(30).
(24)
Svola=-θpyro
(25)
Snonv=-θglow
(26)
Sliq=θads
(27)
SH2Og=-θads+0.53θcomb
(28)
Sp=θpyro-θcomb
(29)
SO2=-2.67θglow-1.33θcomb
(30)
SCO2=3.67θglow+1.80θcomb
The source terms of water vapor, oxygen and carbon dioxide include gases generated due to combustion. It was assumed that only complete combustion occurs. When estimating the coefficients in the formula for glowing of non-volatile components, the non-volatile component is treated as pure carbon. Thus, the reaction is C+O2=CO2. The coefficients can be simply derived by this reaction equation. As for burning of pyrolysis gas, the composition of pyrolysis gas reported in Fredlund’s paper[20] was used to estimate the average composition. The calculation result is that complete combustion of 1kg of pyrolysis gas consumes 1.33 kg of oxygen, generates 1.80 kg carbon dioxide and 0.53 kg of water vapor.

2.5.2 Source terms in enthalpy equation

Source terms in enthalpy equation are shown in Eqs. (31)~(34).
(31)
Qads=θads Δ Lads
(32)
Qpyro=θpyro Δ Lpyro
(33)
Qglow=θglow Δ Lglow
(34)
Qcomb=θcomb Δ Lcomb
Where △Lads=2260 kJ/kg represent the latent heat of water vapor adsorption, △Lpyro=-3590 kJ/kg represent the latent heat of pyrolysis of volatile component, △Lglow=25000 kJ/kg represent the latent heat of non-volatile components(combustion heat of carbon[21] was used here), △Lcomb=17760 kJ/kg represent the latent heat on combustion of pyrolysis gas (combustion heat of Japanese maple[22] was used here), respectively.

3. Numerical Simulation Methodology

The governing equations were discretized and solved numerically. Advection term and diffusion term were discretized by first order upwind difference and centered difference schemes, respectively. The source term was linearized and split into positive and negative parts, to prevent the appearance of nonphysical negative values like mass fraction[23]. Backward Euler method was implied on time integration of governing PDEs. For ODEs like Eq. (2), forward Euler method was used. Iteration inside each time increment were introduced. The convergence criterion in each iteration in a single time step is 1 × 10-4.

4. Simulation on Case of Standard Fire Test

4.1 Target experiment

Simulation was conducted based on the condition of an experiment conducted by Harada et al.[1]. GLT larch with 1200 × 1000 mm surface size and 100 mm thickness were heated by a small heating furnace from one side according to ISO 834 for 60 minutes. After heating, the wall was cooled down in various air supply rate (0.0067- 0.0786 kg/m2s, air supply rate per surface area of wall) for 180 minutes. The average oven dry density of cut-off samples of specimens is 463 kg/m3. The schematics of experiment is shows in Figure 2. The result of the experiment No.7 was used, for which the air supply rate was medium (0.041 kg/m2s).

4.2 Conditions of simulation

4.2.1 Initial conditions

The initial conditions of simulation are shown in Table 1.

4.2.2 Boundary conditions

The boundary conditions for enthalpy equations at the front and rear sides were expressed by Eqs. (35) and (36). Furnace emissivity was set to 0.95. Convective heat transfer coefficient Hfront and Hrear were set to 25 W/m2 and 10 W/m2, respectively. Subscripts 0 and 500 denote the grid number, where 0 is front surface and 500 is rear surface.
(35)
qfront=ɛ0 [Hfront(Tfurn-T0)+0.95σ(Tfurn4-T04)]
(36)
qrear=ɛ500 [Hrear(Tair-T500)+0.95σ(Tair4-T5004)]
For pressure diffusion equation, pressure at heating surface and non-heating surface, were set to be equal to atmosphere pressure, 101325 Pa.
(37)
P0=P500=101325Pa
For liquid water mass conservation equation, second type boundary condition was used in mass conservation equation of liquid water. The flow of liquid water at the boundary was set to zero since there are no liquid water flux at the boundary of the specimen.
(38)
ɛ0(ρ˜liqvliq-Dliq∂ ρ˜liq∂ x)front~0=ɛ500(ρ˜liqvliq-Dliq∂ ρ˜liq∂ x)500~rear=0
For boundary condition of gas species equation, third type boundary conditions were used. At here, subscript i correspond with component of gases, which are water vapor (H2Og), pyrolysis gas (p), oxygen (O2), nitrogen (N2), and carbon dioxide (CO2).
(39)
(ɛ0ρ˜gasYivgas-ɛ0ρ˜gasDi∂ Yi∂ x)front~0=ɛ0Hm,frontτgas,0ρgas,front(Yi,front-Yi,0)
(40)
(ɛ500ρ˜gasYivgas-ɛ500ρ˜gasDi∂ Yi∂ x)500~rear=ɛ500Hm,rearτgas,500ρgas,rear(Yi,500-Yi,rear)

4.2.3 Material properties

Although solid components were divided into volatile components and non-volatile components in this model, it is very difficult to obtain material properties of volatile and non-volatile components separately. Therefore, it was assumed that the material properties of these two solids are equal to the value of wood.
The thermal conductivity of solids was determined by a series of values of thermal conductivity of wood specimen reported in literatures[25-37]. A regression equation was created based on the literature data. The equation consists of 4 segments, expressing the state that pyrolysis is not yet initiated, pyrolysis in progress, completely charred, and completely charred and cooled down. The critical temperature for pyrolysis initiation and completion were set to be 200 ℃ and 380 ℃.
(41)
k={8.134×10-5(T-273.15)+0.120         (T≤473.15K and r>r∞)-4.090×10-4(T-273.15)+0.218         (473.15K<T≤653.15K and r>r∞)1.833×10-4(T-273.15)-6.931*10-3         (T>653.15K)6.270×10-2         (T≤653.15K and   r≤r∞)
Heat capacity of wood was expressed by Dunlap’s equation[38]. For temperature above 200 ℃, heat capacity was set to constant.
(42)
cwood={4.85 T-212.77(T<473.15K)   2082.01(T≥473.15K)
For solids that completely pyrolyzed, it is assumed that the remaining solids consist entirely of carbon. Specific heat of graphite was used to calculate the specific heat of the solids.
(43)
cgrap=1430+0.356 T-7.32×10-3   T-2
The heat capacity of partially pyrolyzed wood can be obtained by performing linear interpolation for the residual ratio, between point (1, cwood) and (r∞, cgrap).
Porosity was set to change according to charring condition. Porosity for completely charred wood is 1.25 times of oven-dry porosity, based on the observation of Li et al.[39].
(44)
τ={0.25τdry1-r1-r∞+τdry   (r∞≤r<1)(1-1.25τdry)r∞-rr∞+1.25τdry   (0≤r<r∞)
In a porous medium, both liquid water and mixed gas exist inside the pore. Since gases can only occupy the void space outside the areas occupied by liquid water in the pores, the effective porosity of gas is calculated by the following equation:
(45)
τgas=τ(1-ω)
The degree of saturation w can be expressed by Eq. (46).
(46)
ω=ρ˜H2Ol1000τ
Specific permeability was also assumed to change according to degree of charring. The specific permeability of completely charred solid was set to be 10 times larger than that at initial value[39]. For solid completely burnt out, the specific permeability of solid were set to be 105 times of initial value to express the phenomenon that the obstruction of solid matrix to gases and liquid were essentially eliminated when glowing combustion had completed.
(47)
x={xdry101-r1-r∞(r∞≤r<1)xdry104(r∞-rr∞)+1(0≤r<r∞)
The relation of specific permeability of gas at fully dried state and wet state can be expressed by Eq. (48). This equation is derived from the widely used Kozeny-Carman equation[40].
(48)
xgas/x=(τgas3(1-τgas)2)/(τ3(1-τ)2)
Compared to liquid, gas flow can move more freely within the pores. The relation between specific permeability of liquid xliq and gas at dry state x was expressed by Eq. (49). The coefficients were calibrated using data reported by Ai et al.[41].
(49)
x=xliq(1+5.61*10-7xliq-0.6512P)

5. Results and Discussion

Simulation results of temperature, moisture content and charred (colored) depth were expressed and compared with experimental results. In the graphs of results, solid lines represent experimental results, and dotted lines represent numerical results.

5.1 Temperature

Figure 3 shows the numerical and experimental results on temperature. Numerical results and experimental results show good agreements during the heating period. At 60 minutes, specimen temperature reached to about 950 ℃ at the heating surface, 600 ℃ at 20 mm, 100 ℃ at 40 mm, and 50 ℃ at 60 mm. Obvious change in temperature was not observed at 80 and 100 mm. As for surface temperature (at 0 mm), the numerical value is higher than experimental value. This is because the surface temperature was measured by inserting thermocouples from the non-heating surface in the experiments, and measured value might be affected by surrounding furnace gas atmosphere. At 20 mm location, the simulation result is slightly lower than the experimental value after 30 minutes but start to increase quickly after 50 minutes and finally reached to the same value with experimental value at 60 minutes.
During the cooling period, numerical results also have good agreement with experimental results. For 0 mm location, numerical result and experimental result on temperature decreased in the same pattern as furnace temperature. For 20 mm location, numerical result increased quickly, reached to about 800 ℃ at about 70 minutes, and then converged to almost the same value as surface temperature. It can be speculated that non-volatile components are completely consumed at that time. Due to the heat generated by intense glowing, temperature rose significantly. However, for measured temperature at 20 mm, the maximum temperature is just 650 ℃, and the temperature is higher than the surface temperature, implying that glowing combustion of char continued. For 40 mm location, temperature increase after start of cooling period was observed in both experimental and numerical result, while experimental results increased more rapidly. However, the peak value and increasing tendency is similar. For 60-100 mm location, the difference between numerical and experimental results are small. In summary, the model can predict temperature inside timber wall specimen in standard fire test in good agreement with experimental value during both heating and cooling period.

5.2 Moisture content

Figure 4 shows the numerical and experimental results on moisture content. Numerical results start to increase at 10 minutes in 20 mm, 40 minutes in 40 mm, 70 minutes in 60 mm, and 120 minutes in 80 mm. Numerical results increase in the same pattern with experimental results, but the peak value in numerical result is lower.
A bending point exists in numerical results at 20 mm and 40 mm. After the bending point, the moisture content started to decrease rapidly. By comparing Figures 3 and 4 and referencing the corresponding time of bending point in moisture content, it can be found that corresponding temperature at bending point is about 300 ℃. The residual ratio corresponding to this temperature is approximately 0.95, which is just the residual ratio for cracking according to the settings described in section 2.3.3. After crack formation, temperature starts to increase rapidly, which will lead to an increase on equilibrium vapor pressure and conversion rate of liquid water to water vapor. According to the analysis above, it can be concluded that the bending point is caused by the formation of crack.

5.3 Residual ratio and charred depth

Figure 5 shows the numerical result of residual ratio. The residual ratio at 0 mm and 20 mm reached 0.25 at about 3 minutes and 50 minutes, which corresponds with that the pyrolysis of volatile components had almost finished. For 40 mm, the residual ratio started to decrease at about 80-90 minutes and keeps decreasing at a relatively slow speed, due to pyrolysis of volatile components. Decrease of residual ratio at 40 mm almost stopped at about 140 minutes. Change of residual ratio at 60~100 mm location were not observed, which means that pyrolysis did not occur at these locations.
By using the calculated residual ratio, numerical result of surface degradation, charred, and colored depth can be evaluated. At here, degradation front was defined as the location of surface grid (grid No.0). Charred front was defined as the location where residual ratio equal to 0.25. Colored front was defined as the location where residual ratio equal to 0.99. Degradation is the length change according to shrinkage and burnt-out. Three types of depth L were calculated by Eq. (50). The calculated results were compared with experimental results. The results are shown in Table 2. It can be concluded that numerical results on charred depth have approximately reproduced the charred depth measured in experiment. However, the difference in burnt-out depth and colored depth is obvious.
For burnt-out depth, it can be concluded that numerical result is overestimated. Since the burnt-out depth is calculated by the overall surface shrinkage of the specimen, the burnt-out depth at here represents the sum of shrinkage due to pyrolysis of wood and glowing of char. The overestimation might be caused by the following reasons. As for pyrolysis of wood, the overestimation on shrinkage distance might be caused by the shrinkage factor η, expressed in Eq. (12). Since the specimen used in experiment is GLT larch, the direction of annual ring is mixed in the experiment, which means that the real shrinkage factor might be smaller than the value used in the calculation. As for glowing combustion of char, it was assumed that the amount of shrinkage distance increases linearly according to the decrease of residual ratio, but the actual situation may be more complicated. For realistic prediction, the rate of glowing combustion and the corresponding shrinkage should be modelled further.
As for the colored depth, the numerical result is about 17 mm smaller than experimental value. In the simulation, judging criteria of colored front was defined as the location whereas residual ratio is equal to 0.99, with the image that color of wood changes quickly after initiation of pyrolysis. However, as for experimental results, the maximum temperature at 60 mm was about 150 ℃ in measurement according to Figure 3. Since measured coloring depth is 64 mm, coloring temperature should be lower than 150 ℃. Pyrolysis did not occur at this temperature. To increase the precision on prediction of colored front, it is necessary to find a more appropriate method to locate colored front in numerical simulation.
(50)
L=0.1-∑i500Δ xi

6. Conclusions

In this paper, a one-dimension numerical model was proposed to analyze the heat and mass transfer process of wood under fire heating and cooling. The mass conservation in solid, liquid and gas phase, as well as the total enthalpy conservation of all substances, were considered. Adsorption and desorption of moisture content, pyrolysis of volatile components, glowing combustion of non-volatile component and burning of pyrolysis gas, were included in the model. Length change of specimen and surface cracking were also considered.
A simulation was conducted based on condition of standard fire resistance test on glue laminated larch wall, reported in previous paper. Temperature, moisture content, and charring depth measured in experiment were compared with numerical results. Numerical results of temperature agreed well with experimental results in general, both in the heating and cooling period. However, the phenomenon that the internal temperature is higher than the surface temperature during the cooling process was not well reproduced. Proposed numerical model can predict change on moisture content by desorption and re-adsorption of water correctly, and the time that moisture content reached its maximum value was close to experimental results. Numerical result of charred depth is close to experimental result. However, burnt-out depth is overestimated and colored depth is underestimated.
In summary, this model can be used to predict the temperature, moisture content and charring history of timber specimen in ISO834 standard fire test, during heating and cooling process. The predicted results are in reasonable agreement with experimental results. Further verification and improvement are desirable, for example, to find a more appropriate method to locate charred and colored fronts in simulation.

Nomenclature

Alphabets
a conversion factor in reaction rate equation, -
A frequency factor, s-1
b coefficient in adsorption equation, s-1Pa-1
c heat capacity, J/(kg.K)
dx grid length, m
D diffusion coefficient, m/s
E activation energy, J/mol
F mass ratio of pseudo components that can be pyrolyzed up to 900 ℃, kg/kg
H convective heat transfer coefficient, W/(m2.K)
Hm mass transfer coefficient, m/s
k thermal conductivity, W/(m.K)
L latent heat, kJ/kg
m mass flux, kg/(m2.s)
M molecular weight, kg/mol
n reaction order, -
P pressure, Pa
q heat flux, W/m2
Q heat generation rate, W/m3
r residual ratio, kg/kg
R ideal gas constant, 8.314J/(mol.K)
S mass source term, kg/(m3.s)
T temperature, K
v velocity, m/s
W weight based moisture content, kg/kg
Y mass ratio, kg/kg
Greek Letters
α coefficient in capillary pressure equation, -
β width depth ratio of crack, -
δ the ratio of the surface in contact with the air to the total surface area of the heated part of the specimen in a certain grid, -
ϵ ratio of remaining solid volume area to total area, -
η shrinkage factor, -
θ reaction rate, kg/(m3.s)
x specific permeability, m2
μ kinematic viscosity, Pa.s
ρ density, kg/m3
ρ~ mass of species per volume of wood, kg/m3
σ stefan-boltzmann constant, 5.67 × 10-8 W/(m2.K4)
τ porosity, m3/m3
∅ variable in general conserve equation
∅~ flux in general conserve equation
x~ view factor, -
ω saturation degree, -
Subscripts
ads adsorption
air air
CO2 carbon dioxide
dry oven dry
flam flaming
gas gas
glow glowing
H2Og water vapor
i,j index
ini initial
liq liquid
N2 nitrogen
O2 oxygen
p/pyro pyrolysis
sol solid

Notes

Author Contributions

Conceptualization, A. Sun and K. Harada; methodology, A. Sun and K. Harada; software, A. Sun; validation, A. Sun, K. Harada and D. Nii; formal analysis, A. Sun; investigation, A. Sun; resources, K. Harada, D. Nii; data curation, A. Sun; writing-original draft preparation, A. Sun; writing-review and editing, A. Sun, K. Harada, D. Nii; visualization, A. Sun; supervision, K. Harada; project administration, A. Sun; funding acquisition, A. Sun. All authors have read and agreed to the published version of the manuscript.

Conflicts of Interest

The authors declare no conflict of interest.

Acknowledgments

This work is supported by JSPS Grant-in-Aid for Research Activity Start-up, number JP 24K22996. The authors appreciate all the support received.

Figure 1.
Image of the crack model.
KIFSE-f03f9a8cf1.jpg
Figure 2.
The illustration of the experiment.
KIFSE-f03f9a8cf2.jpg
Figure 3.
Numerical and experimental results on temperature.
KIFSE-f03f9a8cf3.jpg
Figure 4.
Numerical and experimental results on moisture content.
KIFSE-f03f9a8cf4.jpg
Figure 5.
Numerical and experimental results on moisture content.
KIFSE-f03f9a8cf5.jpg
Table 1
Summary of Initial Conditions Used in Simulation
Variable Type Value Reference
Time Interval Δt 0.05 s -
Grid Number N 501 -
Grid Length dx 2 × 10−4 m -
Initial Temperature T 10.1 °C Temperature at the start of experiment [1]
Initial Moisture Content W 12.2 wt.% Measured value in experiment [1]
Oven Dried Density ρdry 463 kg/m3 Measured using cut-off samples [1]
Initial Gas Permeability χ 1.2 × 10−16 m2 Values for wood with similar density [20]
Initial Porosity (Oven Dried) τ 0.647 Values for wood with similar density [20]
Shrinkage Factor η 0.72 Value of Japanese Larch in radial direction [24]
Table 2
Results on Burn-Out, Charred and Colored Depth
Type Experimental Numerical
Burnt-out 6.0 mm 35.4 mm
Charred 42.0 mm 37.9 mm
Colored 64.0 mm 47.0 mm

References

1. K. Harada, A. Sun, S. Makino and D. Nii, “Burning Behaviour of GLT Walls During Cooling Period after ISO 834 Exposure in a Small Furnace”, Fire Technology, Vol. 60, pp. 2539-2557 (2023), https://doi.org/10.1007/s10694-023-01483-8.
crossref
2. ISO834, "Fire-resistance tests-Elements of building construction", International Organization for Standardization (1999).

3. H. Kimura, T. Suzuki, T. Endo, T. Hokibara, Y.Hasemi, J. Suzuki and K. Kagiya, "Dynamic Measurement of Temperature and Moisture Content changing in Glulam Timber Beam exposed to Fire Heating", Fire safety, Summaries of Technical Papers of Annual Meeting, AIJ (2022).

4. H. Niwa, H. Enomoto, N. Sakata, M. Sadahiro and Y. Kurihara, "Fire Resistance Performance of Build-up Laminated Veneer Lumber: Part 3 Fire Resistance Tests of Column and Beam", Fire Safety, Summaries of Technical Papers of Annual Meeting, AIJ (2020).

5. R. Dârmon and O. Lalu, “The Fire Performance of Cross Laminated Timber Beams”, Procedia Manufacturing, Vol. 32, pp. 121-128 (2019), https://doi.org/10.1016/j.promfg.2019.02.192.
crossref
6. M. Khelifa, A. Khennane, M. El Ganaoui and Y. Rogaume, “Analysis of the Behavior of Multiple Dowel Timber Connections in Fire”, Fire Safety Journal, Vol. 68, pp. 119-128 (2014), https://doi.org/10.1016/j.firesaf.2014.05.024.
crossref
7. J. König and L. Walleij, "One-Dimensional Charring of Timber Exposed to Standard and Parametric Fires in Initially Unprotected and Postprotection Situations", SP Technical Research Institute of Sweden, Wood Technology, Stockholm, Sweden (1999).

8. R. Pečenko, S. Svensson and T. Hozjan, “Modelling Heat and Moisture Transfer in Timber Exposed to Fire”, International Journal of Heat and Mass Transfer, Vol. 87, pp. 598-605 (2015), https://doi.org/10.1016/j.ijheatmasstransfer.2015.04.024.
crossref
9. T. Suzuki, "Evaluation of Influence of Heat and Water Transfer in Wooden Members Exposed to Fire Heating", Waseda University (2021).

10. B. Fredlund, “Modelling of Heat and Mass Transfer in Wood Structures During Fire”, Fire Safety Journal, Vol. 20, No. 1, pp. 39-69 (1993), https://doi.org/10.1016/0379-7112(93)90011-E.
crossref
11. K. M. Bryden, K. W. Ragland and C. J. Rutland, “Modeling Thermally Thick Pyrolysis of Wood”, Biomass Bioenergy, Vol. 22, No. 1, pp. 41-53 (2002), https://doi.org/10.1016/S0961-9534(01)00060-5.
crossref
12. Y. Chatani and K. Harada, “Numerical Prediction of Glowing Combustion of Glue Laminated Larch Wood Heated by Constant Radiant Heat Flux”, Journal of Environmental Engineering (Transactions of AIJ), Vol. 86, No. 790, pp. 863-872 (2021), https://doi.org/10.3130/aije.86.863.
crossref
13. G. A. Spolek and O. A. Plumb, “Capillary Pressure in Softwoods”, Wood Science and Technology, Vol. 15, pp. 189-199 (1981), https://doi.org/10.1007/BF00353471.
crossref
14. K. O. Davidsson and J. B. C. Pettersson, “Birch Wood Particle Shrinkage During Rapid Pyrolysis”, Fuel, Vol. 81, No. 3, pp. 263-270 (2002), https://doi.org/10.1016/S0016-2361(01)00169-7.
crossref
15. N. E. Bixler, "NORIA: A Finite Element Computer Program for Analyzing Water, Vapor, Air and Energy Transport in Porous Media", Sandia National Lab (1985).

16. H. Kimura, T. Suzuki, T. Hokibara, Y. Hasemi and R. Takase, "Measurement of Moisture Desorption from Wood Under Several Temperature and Humidity Conditions and Analysis of the Effect of Sorption on Heat and Moisture Transfer in Wood Under Fire", Fire Safety, Summaries of Technical Papers of Annual Meeting, AIJ (2023).

17. A. Sun, K. Harada, D. Nii and J. Yamaguchi, “Measurements of Thermal Decomposition Rates of Several Types of Wood and Estimation of Reaction Rate Parameters”, Bulletin of Japan Association for Fire Science and Engineering, Vol. 71, No. 2, pp. 25-36 (2021), https://doi.org/10.11196/kasai.71.2_25.
crossref
18. Y. Chatani and K. Harada, “Measurement of Char Oxidation Rate of Larch Glue Laminated Timber”, Fire Science and Technology, Vol. 43, No. 1, pp. 1-16 (2024), https://doi.org/10.3210/fst.43.1.
crossref
19. A. Sun, K. Harada and D. Nii, “Experimental Research on Moisture Transfer, Burning and Charring Behavior of Glue Laminated Larch Under Fire Heating Using Cone Calorimeter”, Fire Technology, Vol. 60, pp. 2559-2579 (2024), https://doi.org/10.1007/s10694-024-01545-5.
crossref
20. B. Fredlund, "A Model for Heat and Mass Transfer in Timber Structures During Fire: A Theoretical, Numerical and Experimental Study" (1988).

21. T. Kashiwagi and H. Nambu, “Global Kinetic Constants for Thermal Oxidative Degradation of a Cellulosic Paper”, Combustion and Flame, Vol. 88, pp. 3-4pp. 345-368 (1992).
crossref
22. T. Tanaka, "Introduction on Fire Safety Engineering in Architecture", The Building Center of Japan (2002).

23. S. V. Patankar, "Numerical Heat Transfer and Fluid Flow", Hemisphere Publishing Corproation (1980).

24. A. Sun, K. Harada, D. Nii, E. Kuroda and Y. Chatani, "Measurement of Shrinkage of Larch and Japanese Cedar During Constant Temperature Heating", Research Reports, Architecture Institute of Japan, Kinki Branch (2021).

25. B. Adl-Zarrabi, L. Boström and U. Wickström, “Using the TPS Method for Determining the Thermal Properties of Concrete and Wood at elevated Temperature”, Fire and Materials, Vol. 30, No. 5, pp. 359-369 (2006), https://doi.org/10.1002/fam.915.
crossref
26. N. Bénichou and M. A. Sultan, “Thermal Properties of Lightweight-Framed Construction Components at Elevated Temperatures”, Fire and Materials, Vol. 29, No. 3, pp. 165-179 (2005), https://doi.org/10.1002/fam.880.
crossref
27. W. Wijayanti, “The Physical Properties (Enthalpy and Thermal Conductivity) of Mahogany Wood Induced by Pyrolysis Temperature Process”, Applied Mechanics and Materials, Vol. 664, pp. 215-220 (2014), https://doi.org/10.4028/www.scientific.net/AMM.664.215.
crossref
28. E. Steau and M. Mahendran, “Elevated Temperature Thermal Properties of Fire Protective Boards and Insulation Materials for Light Steel Frame Systems”, Journal of Building Engineering, Vol. 43, (2021), https://doi.org/10.1016/j.jobe.2021.102571.
crossref
29. European Committee for Standardization, "Eurocode 5: Design of timber structures - Part 1-2: General - Structural fire design" (2004).

30. G. Thomas, "Fire Resistance of Light Timber Framed Walls and Floors", University of Canterbury (1996).

31. M. Z. Naser, “Properties and Material Models for Common Construction Materials at Elevated Temperatures”, Constructions and Building Materials, Vol. 215, pp. 192-206 (2019), https://doi.org/10.1016/j.conbuildmat.2019.04.182.
crossref
32. M. Janssens, "Thermo-physical Properties for Wood Pyrolysis Models", Pacific Timber Engineering Conference, pp. 607-618 (1994).

33. R. M. Knudson and A. P. Schniewind, “Performance of Structural Wood Members Exposed to Fire”, Forest Products Journal, Vol. 25, No. 2, pp. 23-32 (1975).

34. A. Frangi, "Brandverhalten von Holz-Beton-Verbunddecken", ETH Zurich (2001). https://doi.org/10.3929/ethz-a-004273454.

35. J. R. Mehaffey, P. Cuerrier and G. Carisse, “A Model for Predicting Heat Transfer Through Gypsum-Board/Wood-Stud Walls Exposed to Fire”, Fire and Materials, Vol. 18, No. 5, pp. 297-305 (1994), https://doi.org/10.1002/fam.810180505.
crossref
36. T. Z. Harmathy, "Properties of Building Materials at Elevated Temperatures", Paper No. 1080, National Research Council of Canada (1983).

37. T. Ouchi, “Thermal Conductivity of Wood at High Temperatures”, Research Reports, Architecture Institute of Japan, pp. 785-786 (1987).

38. F. Dunlap, "The Specific Heat of Wood", U.S. Dept. of Agriculture, Forest Service (1912).

39. Y. Li, B. Y. Lattimer and S. W. Case, "Measurement and Modelling of Thermal and Physical Properties of Wood Construction Materials", Constructions and Building Materials, Vol. 284 (2021). https://doi.org/10.1016/j.conbuildmat.2021.122780.

40. A. Rabbani and S. Jamshidi, “Specific Surface and Porosity Relationship for Sandstones for Prediction of Permeability”, International Journal of Rock Mechanics and Mining Sciences, Vol. 71, pp. 25-32 (2014), https://doi.org/10.1016/j.ijrmms.2014.06.013.
crossref
41. W. Ai, H. Duval, F. Pierre and P. Perré, “A Novel Device to Measure Gaseous Permeability Over a Wide Range of Pressures: Characterisation of Slip Flow for Norway Spruce, European Beech, and Wood-Based Materials”, Holzforschung, Vol. 71, No. 2, (2016), https://doi.org/10.1515/hf-2015-0264.
crossref


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next