1. K. Harada, A. Sun, S. Makino and D. Nii, “Burning Behaviour of GLT Walls During Cooling Period after ISO 834 Exposure in a Small Furnace”, Fire Technology, Vol. 60, pp. 2539-2557 (2023),
https://doi.org/10.1007/s10694-023-01483-8.
2. ISO834, "Fire-resistance tests-Elements of building construction", International Organization for Standardization (1999).
3. H. Kimura, T. Suzuki, T. Endo, T. Hokibara, Y.Hasemi, J. Suzuki and K. Kagiya, "Dynamic Measurement of Temperature and Moisture Content changing in Glulam Timber Beam exposed to Fire Heating", Fire safety, Summaries of Technical Papers of Annual Meeting, AIJ (2022).
4. H. Niwa, H. Enomoto, N. Sakata, M. Sadahiro and Y. Kurihara, "Fire Resistance Performance of Build-up Laminated Veneer Lumber: Part 3 Fire Resistance Tests of Column and Beam", Fire Safety, Summaries of Technical Papers of Annual Meeting, AIJ (2020).
6. M. Khelifa, A. Khennane, M. El Ganaoui and Y. Rogaume, “Analysis of the Behavior of Multiple Dowel Timber Connections in Fire”, Fire Safety Journal, Vol. 68, pp. 119-128 (2014),
https://doi.org/10.1016/j.firesaf.2014.05.024.
7. J. König and L. Walleij, "One-Dimensional Charring of Timber Exposed to Standard and Parametric Fires in Initially Unprotected and Postprotection Situations", SP Technical Research Institute of Sweden, Wood Technology, Stockholm, Sweden (1999).
9. T. Suzuki, "Evaluation of Influence of Heat and Water Transfer in Wooden Members Exposed to Fire Heating", Waseda University (2021).
12. Y. Chatani and K. Harada, “Numerical Prediction of Glowing Combustion of Glue Laminated Larch Wood Heated by Constant Radiant Heat Flux”, Journal of Environmental Engineering (Transactions of AIJ), Vol. 86, No. 790, pp. 863-872 (2021),
https://doi.org/10.3130/aije.86.863.
15. N. E. Bixler, "NORIA: A Finite Element Computer Program for Analyzing Water, Vapor, Air and Energy Transport in Porous Media", Sandia National Lab (1985).
16. H. Kimura, T. Suzuki, T. Hokibara, Y. Hasemi and R. Takase, "Measurement of Moisture Desorption from Wood Under Several Temperature and Humidity Conditions and Analysis of the Effect of Sorption on Heat and Moisture Transfer in Wood Under Fire", Fire Safety, Summaries of Technical Papers of Annual Meeting, AIJ (2023).
17. A. Sun, K. Harada, D. Nii and J. Yamaguchi, “Measurements of Thermal Decomposition Rates of Several Types of Wood and Estimation of Reaction Rate Parameters”, Bulletin of Japan Association for Fire Science and Engineering, Vol. 71, No. 2, pp. 25-36 (2021),
https://doi.org/10.11196/kasai.71.2_25.
18. Y. Chatani and K. Harada, “Measurement of Char Oxidation Rate of Larch Glue Laminated Timber”, Fire Science and Technology, Vol. 43, No. 1, pp. 1-16 (2024),
https://doi.org/10.3210/fst.43.1.
19. A. Sun, K. Harada and D. Nii, “Experimental Research on Moisture Transfer, Burning and Charring Behavior of Glue Laminated Larch Under Fire Heating Using Cone Calorimeter”, Fire Technology, Vol. 60, pp. 2559-2579 (2024),
https://doi.org/10.1007/s10694-024-01545-5.
20. B. Fredlund, "A Model for Heat and Mass Transfer in Timber Structures During Fire: A Theoretical, Numerical and Experimental Study" (1988).
21. T. Kashiwagi and H. Nambu, “Global Kinetic Constants for Thermal Oxidative Degradation of a Cellulosic Paper”, Combustion and Flame, Vol. 88, pp. 3-4pp. 345-368 (1992).
22. T. Tanaka, "Introduction on Fire Safety Engineering in Architecture", The Building Center of Japan (2002).
23. S. V. Patankar, "Numerical Heat Transfer and Fluid Flow", Hemisphere Publishing Corproation (1980).
24. A. Sun, K. Harada, D. Nii, E. Kuroda and Y. Chatani, "Measurement of Shrinkage of Larch and Japanese Cedar During Constant Temperature Heating", Research Reports, Architecture Institute of Japan, Kinki Branch (2021).
25. B. Adl-Zarrabi, L. Boström and U. Wickström, “Using the TPS Method for Determining the Thermal Properties of Concrete and Wood at elevated Temperature”, Fire and Materials, Vol. 30, No. 5, pp. 359-369 (2006),
https://doi.org/10.1002/fam.915.
26. N. Bénichou and M. A. Sultan, “Thermal Properties of Lightweight-Framed Construction Components at Elevated Temperatures”, Fire and Materials, Vol. 29, No. 3, pp. 165-179 (2005),
https://doi.org/10.1002/fam.880.
28. E. Steau and M. Mahendran, “Elevated Temperature Thermal Properties of Fire Protective Boards and Insulation Materials for Light Steel Frame Systems”, Journal of Building Engineering, Vol. 43, (2021),
https://doi.org/10.1016/j.jobe.2021.102571.
29. European Committee for Standardization, "Eurocode 5: Design of timber structures - Part 1-2: General - Structural fire design" (2004).
30. G. Thomas, "Fire Resistance of Light Timber Framed Walls and Floors", University of Canterbury (1996).
32. M. Janssens, "Thermo-physical Properties for Wood Pyrolysis Models", Pacific Timber Engineering Conference, pp. 607-618 (1994).
33. R. M. Knudson and A. P. Schniewind, “Performance of Structural Wood Members Exposed to Fire”, Forest Products Journal, Vol. 25, No. 2, pp. 23-32 (1975).
35. J. R. Mehaffey, P. Cuerrier and G. Carisse, “A Model for Predicting Heat Transfer Through Gypsum-Board/Wood-Stud Walls Exposed to Fire”, Fire and Materials, Vol. 18, No. 5, pp. 297-305 (1994),
https://doi.org/10.1002/fam.810180505.
36. T. Z. Harmathy, "Properties of Building Materials at Elevated Temperatures", Paper No. 1080, National Research Council of Canada (1983).
37. T. Ouchi, “Thermal Conductivity of Wood at High Temperatures”, Research Reports, Architecture Institute of Japan, pp. 785-786 (1987).
38. F. Dunlap, "The Specific Heat of Wood", U.S. Dept. of Agriculture, Forest Service (1912).
40. A. Rabbani and S. Jamshidi, “Specific Surface and Porosity Relationship for Sandstones for Prediction of Permeability”, International Journal of Rock Mechanics and Mining Sciences, Vol. 71, pp. 25-32 (2014),
https://doi.org/10.1016/j.ijrmms.2014.06.013.
41. W. Ai, H. Duval, F. Pierre and P. Perré, “A Novel Device to Measure Gaseous Permeability Over a Wide Range of Pressures: Characterisation of Slip Flow for Norway Spruce, European Beech, and Wood-Based Materials”, Holzforschung, Vol. 71, No. 2, (2016),
https://doi.org/10.1515/hf-2015-0264.