Abstract

As building height increases, the escalator is used more frequently. Individuals who are unable to hold safety railings may lose balance during fire alarms or emergency stops. Shorter stair heights shift the body’s center of gravity, making movement easier. This experimental study assessed evacuation times for varying stair heights when escalators were used during emergencies. Escalator accidents were investigated, and both domestic and international studies on stair height were analyzed. Evacuation efficiency based on stair height was also evaluated through a simulation. Our findings indicate that smaller step heights resulted in a shorter evacuation time and facilitated safer evacuation. Therefore, if the simulation program is further refined, it could be applied in real-world scenarios and conduct further research on evacuations.

1. Introduction

The global elevator market is projected to grow annually by an average of 4.64%[1]. By 2024, it is expected to reach 161.7 billion USD. This growth is driven by the introduction of smart technologies, the expansion of Internet of Things (IoT)-based platforms, an aging population, and increased construction activity[2]. In many countries, the number of elevators used for vertical and horizontal transportation is rapidly increasing owing to urbanization and the surge in high-rise buildings. The increasing number of shopping malls, airports, train stations, and subway stations in metropolitan areas has also increased demand for horizontal transportation systems that can accommodate large crowds. However, with the rise of convenience facilities, the number of related accidents is also increasing annually[3]. These changes have significantly influenced daily life, underscoring the importance of maintaining a balance between work and leisure. For instance, during the Lunar New Year holiday in 2025, Incheon International Airport is projected to record an average of 219,800 daily passengers. As a major hub, the airport serves approximately 106 million passengers annually[4]. Passengers transitioned to cars, often using escalators with luggage. Those traveling by car also use escalators to travel from parking lots to terminals. Most travelers prefer escalators over elevators because of their bulky or heavy luggage. The parking lot currently utilizes the existing elevator shaft during expansion; however, the newly installed escalator differs from the original in step height. This disparity is particularly noticeable when the escalator is stationary. Compared with general stairs, escalator steps are usually higher, requiring users to lift their knees higher than normal. When descending, the stairs may be higher than what a person is accustomed to, making it harder to maintain balance, especially in the case of an emergency stop or accident, which may increase the risk of falls. To prevent such accidents, it is essential to be mindful of step height and to follow established safety rules. When using an escalator, the notice sign typically reads in English, ‘Hold the handrail.’ However, most users do not follow this instruction[5]. This behavior may be related to concerns regarding dirt from shared surfaces or the inconvenience of holding their cell phones. Direct observations of passengers on subway station escalators showed that, on average, only 3 out of 40 individuals held handrails, while the rest did not use handrails or simply moved with their elbows. Because of this neglect of safety rules, escalator accidents have increased, underscoring the need for better preparation and preventive measures. Large department stores and shopping malls often lack adequate evacuation routes compared to their capacity[6]. Evacuation stairs at department stores and large shopping malls are less noticeable and are intended to encourage users to focus more on shopping using escalators. Consequently, in the event of a fire or disaster, most passengers attempt to evacuate using escalators that have stopped in response to fire alarms. Previous studies have examined evacuation methods involving escalators in subway stations[7] and simultaneous evacuation using escalators and stairs[8-10]. However, research on the effectiveness of escalator-based evacuation remains limited. To address this gap, an evacuation study using Pathfinder was conducted. Escalators are widely installed in shopping malls and subway stations and are primarily used by unfamiliar people rather than those familiar with the building layout. During a disaster, instead of quickly locating evacuation stairs, occupants often attempt to evacuate via the escalators they usually use. In fire emergencies, escalators are frequently used for evacuation; however, their safety is compromised when they are stopped, as users may struggle to maintain balance owing to step height differences, potentially leading to accidents. Moreover, elevators should be avoided in fire situations because of the risk of exposure to smoke and flames, although fire-rated elevators can be used if they meet specific safety standards[7,11].
This study investigates how reducing escalator step height affects evacuation when the escalator is stopped, whether going up or down. Escalators are widely installed in commercial and transportation facilities, but they account for a considerable proportion of elevator-related accidents, particularly among vulnerable groups such as children and older adults. Many of these incidents are attributed to user negligence, inconsistent step heights, or insufficient safety compliance with safety guidelines. Additionally, this study was conducted to confirm the efficiency of using an escalator tread as a staircase during various disasters. The goal was to reduce the evacuation time when evacuating using an escalator.

2. Background

2.1. Escalator installation status

As buildings increase in size, amenities, such as elevators, escalators, and moving walkways, are included[3]. The number of elevators installed is increasing every year. According to data from the National Elevator Information Center, the total number of elevators in Korea is projected to reach 866,669 by 2025. Escalators account for 94.6% of the total, elevators for 4.1%, and moving walkways for 0.7%.
Department stores, large shopping malls, and large box stores have favored installing escalators rather than elevators because of the consumer behavior in retail environments. Customers tend to browse slowly across multiple floors, resulting in frequent movements between levels and extended stays[12]. In large stores, many customers use shopping carts; therefore, conveyor belts are installed to ensure efficient movement.
Table 1 shows that escalators were installed in 48.72% of large shopping malls and 23.53% of subway stations[9]. In addition to Lines 1-8, which are managed by the Seoul Transportation Corporation, most subway stations—including those on the Gyeongui-Jungang, Shinbundang, and Suinbundang Lines—are equipped with escalators.

2.2. Escalator accident factors

Escalators accounted for 4.91% of all elevator-related facilities. In 2019, one major accident was reported, and two more occurred in 2024, resulting in death, hospitalization for more than a week, or treatment lasting over three weeks. Falls on escalators can result in minor abrasions or fatal outcomes, with varying impacts based on sex[13-15]. In general, taller staircases in buildings are associated with higher accident rates among older adults compared to younger individuals[16].
Escalator accidents often result from user negligence or unsafe usage patterns, such as falling and jamming. Younger individuals are more likely to experience accidents, such as falls or collisions, because of curiosity and exploratory behavior. Conversely, older individuals, who generally have lower cognitive abilities and slower physical responses, are more likely to stumble or trip. Unlike elevator accidents, escalator accidents typically impact vulnerable populations, particularly children under 13 years (20.7%) and seniors aged 65 years or older (38.3%) (Kwon et al. 2012). During summer, accidents are mainly caused by sand. In addition to user behavior, accidents may also result from mechanical problems or defects in the escalator itself. Common causes include damaged steps, step jamming, cracked glass at the bottom of the handrail, and smoke generation[17,18].
According to the Seoul Transportation Corporation Management Evaluation Report 2024, 1,098 cases of user negligence were recorded. Of these, 4.29% were classified by accident type, including falls (913 cases, 83.15%), accidents caused by jamming (68 cases, 6.19%), falls caused by a third party (39 cases, 3.55%), and stoppages due to defective parts. The sign ‘Hold the handrail’ is prominently displayed on escalators; however, most passengers do not comply. Several factors contribute to this behavior, such as holding a cell phone while using the escalator or avoiding the handrail because of concerns about dirt or contamination. Even when passengers are carrying mobile phones, many deliberately avoid touching the handrails for hygiene reasons[19]. With rising awareness of personal hygiene and hand cleanliness, passengers using escalators have been seen as not holding handrails[20].
Noise pollution is also a widespread issue in modern times, and the use of noise-canceling earphones or headsets has become relatively high[21]. These devices block external sounds so effectively that once worn, no sound can be heard, even if an accident occurs at the top of the escalator.
Article 18 of the ‘Operation Regulations on Safe Operation and Management of Elevators,’ a notice issued by the Ministry of the Interior and Safety, states: ‘When using an escalator or inclined moving walkway, you must hold the handrail’[22]. Furthermore, the practice of “tightrope walking” during the 2002 World Cup led to the adoption of walking escalators. However, this practice has led to numerous accidents involving not only the individuals themselves but also third parties, owing to falls while walking or running on escalators[23]. Such incidents often injure both the person using the escalator and the passengers behind them simultaneously. Older adults and people with disabilities, who may struggle to keep up with the escalator’s standard speed of 0.5 m/s, are particularly vulnerable[24].
If an escalator stops suddenly—whether triggered by a fire signal or losing its center of gravity owing to an emergency stop from pinching, a fall, or a collision by a third party—reducing the height between the tread and the stepping board may help lower the risk of imbalance and falls.

2.3. Comparison of domestic and international laws

Escalator height regulations in the USA (Canada), the United Kingdom (Europe), and South Korea (ASME[25]; BS EN115[26]; Escalator Safety Standards[27]).
According to Figure 1, escalator regulations in the USA (Canada) mandate a maximum step height of 8.5 inches (220 mm). In the UK (Europe) and South Korea, the maximum allowed step height for escalators is 0.24 m (240 mm).
Stair height regulations in the USA, the UK, and South Korea (Rules on Standards for Evacuation and Fire Prevention Structures of Buildings[28]).
According to USA stair regulations, the height of the staircase should not exceed 734 inches, and the deviation of each step should not exceed 38 inches. Additionally, the UK's stairs regulations state that the height of the stairs should be between 150 and 220 mm, and no deviations are permitted between steps.
Compared with other countries, South Korea's stair height regulations are limited. Current guidelines specify that the height of the stairs in elementary schools should not exceed 160 mm, and those in middle and high schools should not exceed 180 mm; however, no regulations exist for other types of buildings. A comparison of stair heights in buildings with escalators across the U.S., U.K., and South Korea highlights notable differences. In the U.S., normal stairs are 7 inches high, whereas escalator steps are 8.5 inches high. In the U.K., normal building stairs range from 150 to 220 mm, while escalators are 240 mm high. In South Korea, the heights of normal building stairs are 160 mm and 180 mm, which is significantly lower than the height of the escalator steps.
Elevator regulations in the USA are outlined in the International Building Code (IBC) Chapter 30 and National Fire Protection Association (NFPA) Code 70, Chapter 6. They are also outlined in ASME A.17.1, which specifies that the depth of the stair treads must be at least 400 mm (15.75 in) and the height between treads should not exceed 220 mm (8.5 in). Canada’s escalator regulations (CSAB44) follow the same standard, with a maximum height of 220 mm. In Europe, Regulation 1150 of European Standard EN 8.1.1 states that the height between escalator treads should not exceed 0.24 m. South Korea’s stair height regulation is also set at 0.24 m, consistent with the UK and Europe. In the USA and Canada, escalator stairs are less than 220 mm, whereas in Europe, they are 240 mm, and in South Korea, they are 240 mm. This results in a difference of approximately 38 mm in the USA, up to 90 mm in the UK, and 80 mm in South Korea when comparing general staircase heights to escalator stairs.

3. Methods

3.1. Evacuation simulation conditions

The total number of participants in the simulation was 100 (50 men and 50 women). Of these, 25 men and 25 women were aged 10-39, while the remaining 25 men and 25 women were aged 60-79 years. These age groups were selected due to their high usage of escalators at subway stations, which are commonly used by office workers, students, and older adults. Individuals aged 40 years or older were excluded from the study, as they typically rely on cars for transportation. This study also considered standard human body indices for South Koreans, including walking speed and shoulder width. Because this study employed a computerized evacuation simulation and did not involve actual human participants, formal ethical approval was deemed unnecessary.
Choi et al.[29] reported average evacuation speed values for men and women during downward movement. In the event of a fire or other building disaster, both men and women evacuate faster than normal walking speeds.
Walking vertically, such as climbing stairs or navigating broken escalators, requires greater effort and thus consumes more energy than walking on level ground[30]. According to Frantzich[31], when descending stairs, individuals typically move at speeds ranging from 0.69 to 0.72 m/s, regardless of the stair width. In emergency situations where escalators are used for evacuation, or when rapid movement is required, walking speeds in simulations are often adjusted accordingly. During disasters, evacuation behavior can be influenced by social dynamics. Individuals tend to follow the pace of their companions or those around them[32]. This can affect decisions made by pedestrians while evacuating[33-36].
To evaluate the impact of stair height during evacuation, we conducted an evacuation simulation. The escalator examined was 65 m long—the longest in South Korea—compared with the national average escalator length of 25 m. The tread height varied, with European and domestic regulations set at 240 mm and 220 mm in the USA (215 mm). The actual height of the escalator installed in the extension of the Incheon International Airport was 180 mm. During evacuation, factors such as walking speed and age were incorporated into the model. To compare scenarios in which bottlenecks occurred[37,38], the left lane was assigned to ordinary adult, and the right lane was assigned to older adults based on walking speed.

3.2 .The Pathfinder experiment

The evacuation simulation was conducted six times under different scenarios (Figure 2), and the results were collected using the Pathfinder experiment[39-42].
The simulation experimental conditions were as follows: When the escalator was 65 m long, the escalator step heights were 240, 215, and 180 mm and were computerized three times (pathfinder). When the escalator was 25 m long, the evacuation times for the six conditions were compared by simulating escalator step heights of 240, 215, and 180 mm.
The escalator was set to 65 m to match the longest escalator installed at Guri Station on the Korean light rail, whereas the average length for the other subway stations was 25 m. The stair height was adjusted to 215 mm to comply with the U.S. standard of 220 mm or less, and the minimum height of Incheon International Airport was set to 180 mm to meet the same standard.
In the comparative experiment, when the escalator was stopped, people with slow walking speeds were directed to the right to evacuate, and those with high walking speeds were directed to the left. We experimented with two escalator entrances and two exits. In the event of a disaster, everyone was instructed to use the escalator without distinction. In these situations, both the escalator entrance and exit were set to one, and both scenarios were tested to measure their impact on evacuation time.

4. Results

Table 2 presents the simulation results, analyzing the evacuation time based on stair height during emergency stop situations and fires. Simulations (1, 2, and 3) calculated the time required for all 100 participants to evacuate when the escalator length was 65 m[43]. The available safe egress time (ASET) was defined as the required safe egress time (RSET) plus additional margin time. During emergency stops, the European and Korean standard of 240 mm required 328.5 s for evacuation, while the U.S. standard of 215 mm took 306.0 s, and the 180 mm height took 38.7 s. Furthermore, the evacuation time during emergency situations, such as a fire or disaster, was observed to be 243.0 s for the 240 mm height, 224.0 s for the 215 mm height, and 209.8 s for the 180 mm height, showing a difference of 33.2 s between the fastest and slowest evacuation times.
Simulations 4, 5, and 6 represent the time required for all 100 participants to evacuate when the escalator length was set at 25 m. Evacuation times were recorded as 224.3 s for 240 mm, 211.8 s for 215 mm, and 199.5 s for 180 mm, indicating that the evacuation time varies depending on the height of the stairs. In an emergency, evacuation times were 166.5 s at 240 mm, 156.5 s at 215 mm, and 143.0 s at 180 mm, indicating a maximum evacuation time difference of 23.5 seconds. These results are summarized in Figure 3, which shows that for both 65 m and 25 m escalators, greater step heights were associated with longer evacuation times.
Table 3 shows the evacuation patterns during a disaster or unexpected events, such as emergency stops. A comparison was made between two scenarios: (1) fast evacuation regardless of age or sex, and (2) evacuation when older participants were directed to the right and younger participants to the left. Evacuation times when passing through the designated passages in Table 3 were compared to those when not passing through.
When the escalator length was 65 m and the stair height was 240 mm, the time difference for evacuating in the specified direction was 389.5 s, compared to 283.8 s for evacuating in the order of entry. This resulted in a time difference of 105.7 s, which can be clearly seen in Figure 4.
When comparing the height of the stairs at 180 mm to the length of the escalator at 25 m, the time difference was 241.8 s when traveling left and right and 190.8 s when evacuating quickly in a specific order, as shown in Figure 5. During the simulation, older individuals generally took longer to move to the right, whereas younger participants used the left staircase, even in bottleneck situations where they pushed each other. Additionally, as evacuees started evacuating to the left, they pushed others forward and then returned to the left or moved down before finally turning left to pass through the left gate.
Generally, it takes longer to pass through a gate in the event of a bottleneck.

5. Discussion

This study proposes strategies to increase evacuation efficiency using escalators in various disaster situations. Specifically, it examined how stair height affects evacuees’ movement to the evacuation floor when escalators are not operational. Previous research has shown that evacuation using escalators is feasible in underground settings [9], and can be effective for evacuating people from the upper floors of large underground buildings[8]. During building fires, elevators typically cease operation and transport users to the designated evacuation floor. Similarly, escalators also stop and remain stationary. Passengers must evacuate by using stationary escalators. Research has indicated that using escalators during a fire can alleviate the congestion in evacuation staircases, thereby supporting a more efficient evacuation process[7].
Experiment results demonstrated that reducing the height of escalator stairs shortens evacuation time. Escalator length also plays a significant role in the evacuation time based on the height of the stairs. In the event of clothing or shoe entrapment causing the escalator to stop, users may struggle to move quickly, which is a known challenge. Adherence to safety regulations is crucial for preventing such incidents. Observing the increasing trend of ‘Smombies’ [44] (individuals distracted by smartphones while walking) further emphasizes the importance of prioritizing safety. Additionally, the use of noise-canceling earphones can prevent individuals from becoming aware of their surroundings, potentially leading to collisions or accidents.
Owing to the limitations of current simulations, accurately modeling scenarios such as an individual falling on an escalator or a bag tumbling downward remains difficult. Furthermore, during bottleneck situations, existing programs often unrealistically push individuals towards their original input positions[45]. These limitations highlight the need for further developments in simulation tools to better reflect real-world dynamics. In real-world fire or disaster scenarios, building residents frequently prefer escalators over emergency stairs for evacuation. A simulation-based study was conducted to investigate the effect of escalator stair height on the evacuation efficiency under these conditions. Future studies should integrate more realistic human behavior modeling with dynamic physical interactions to increase the applicability of simulation results to real-world emergencies.

6. Conclusion

This study analyzed the impact of escalator stair height on evacuation efficiency during building emergencies through experimental simulations. The aim of this study was to evaluate the influence of structural design elements, particularly stair height and escalator length, on evacuation speed and safety. The key findings are summarized as follows:

1) Effect of Reducing Escalator Stair Height

Lowering the height of escalator stairs significantly improved the evacuation speed and reduced the likelihood of casualties. For long escalators, the time difference exceeded 30 s, and the effect was particularly noticeable for individuals unfamiliar with the building layout, offering a quicker means of evacuation.

2) Impact of Escalators Length on Evacuation Efficiency

As long escalators become more common in high-rise buildings, the stair height tends to decrease, which may negatively impact evacuation efficiency. As escalators can serve as critical evacuation routes when emergency stairways are difficult to locate, improvements in design and regulatory standards are necessary.

3) Limitations of Simulation Tools and Future Directions

Existing simulation tools (the Pathfinder used in this experiment) have limitations in accurately reflecting dynamic behaviors, such as sudden body movements or falls during emergency stops. Future studies should focus on developing more realistic simulations that incorporate these factors. Additionally, experimental efforts should be made to standardize stair height regulations across different countries. Integrating realistic human behavior models is also essential for enhancing the practicality of evacuation strategies and the effectiveness of disaster response planning.

Notes

Conflicts of Interest

The author declares no conflicts of interest related to this research.

Figure 1.
Escalator height regulations in the USA (Canada), UK, and South Korea.
KIFSE-5544147ff1.jpg
Figure 2.
Escalator height regulations in the USA (Canada), UK, and South Korea.
KIFSE-5544147ff2.jpg
Figure 3.
Comparison graph of evacuation time based on stair height (180 mm, 215 mm, 240 mm) according to escalator length (65 m, 25 m).
KIFSE-5544147ff3.jpg
Figure 4.
Time comparison based on evacuation type for escalator length of 65m and stair height of 240 mm.
KIFSE-5544147ff4.jpg
Figure 5.
Time comparison according to evacuation type based on escalator length of 25 m and stair height of 180 mm.
KIFSE-5544147ff5.jpg
Table 1
Types of Elevators Installed Across Different Buildings
Building use Total Elevator Escalator (%) Wheelchair
Apartment 387,618 386,214 1,161 3.33 243
Neighborhood life 109,813 107,420 2,006 5.92 327
Sales 28,127 10,944 16,989 48.72 194
Transportation 13,690 5,007 8,207 23.53 476
Business facility 40,185 37,612 2,154 6.18 419
Accommodation 20,287 19,637 608 1.74 42
Education/Welfare 39,446 38,153 294 0.84 999
Culture rally 9,027 7,108 1,608 4.61 311
Medical facility 12,060 11,303 677 1.94 80
Factory 28,993 28,481 446 1.28 66
Others 20,713 19,368 663 1.90 682
Total 709,959 671,247 34,873 3,839
Ratio (%) 100 (%) 94.55 (%) 4.91 (%) 0.54 (%)

Source: Ministry of the Interior and Safety.

Table 2
Evacuation Simulation Experiment Results(1)
Escalator length (m) Escalator steep height (mm) Evacuation time in case of emergency stop (sec) Evacuation time in case of disaster (sec)
1 65 240 328.5 243.0
2 215 306.0 224.0
3 180 289.8 209.8
4 25 240 224.3 166.5
5 215 211.8 156.5
6 180 199.5 143.0
Table 3
Evacuation Simulation Experiment Results(2)
Escalator length (m) Escalator steep height (mm) Evacuation time when evacuating in order of entry, regardless of left or right (sec) Evacuation time when the older adults pass to the left and the young pass to the right (sec)
1 65 240 389.5 283.8
2 25 180 241.8 190.8

References

1. IMARC. Elevator and Escalator Market Report by Type (Elevators, Escalators, Moving Walkways), Service (New Installation, Maintenance and Repair, Modernization), End Use (Residential, Commercial), and Region 2025-2033, Available From: https://www.giiresearch.com/report/imarc1675703-movable-walls-market-by-operation-sliding-folding.html (2025).

2. C. H. Lee, C. H. Lee, S. H. Park, Y. J. Lee, P. I. Kim and S. B. Choi, “IoT-based Escalator Failure Prediction System”, Proceedings of the Korean Society of Computer Information Conference, Vol. 27, No. 2, pp. 11-12 (2019).

3. B. S. Kim and P. Park, “A Study on the Safety Management Plan to Prevent Safety Accident Escalator User”, Journal of the Korea Safety Management & Science, Vol. 22, No. 1, pp. 45-50 (2020), https://doi.org/10.12812/ksms.2020.22.1.045.
crossref
4. Newsis. Incheon Airport Lunar New Year Holiday Passengers, Average Daily 219,800‘Highest Ever’, (2025), Available from: https://www.newsis.com/view/NISX20250203_0003050698.

5. C. C. Chew, C. T. Chang, X. J. Lim, H. A. Ibrahim, H. Azmi, N. I. Wahabi, N. S. Hamdan, N. A. Nazan and et al, “The Quality of Escalator Signage for Public Safety in Malaysia: An Observational Study”, Global Health Journal, Vol. 5, No. 4, pp. 198-203 (2021), https://doi.10.1016/j.glohj.2021.10.002.
crossref
6. E. A. Khan, M. A. Ahmed, E. H. Khan and S. C. Majumder, “Fire Emergency Evacuation Simulation of a Shopping Mall Using Fire Dynamic Simulator (FDS)”, Journal of Chemical Engineering, Vol. 30, No. 1, pp. 32-36 (2017), https://doi.org/10.3329/jce.v30i1.34795.
crossref
7. C. Zhabg, W. Xin, J. Chen and H. Shen, “Research on Escalators Used as Evacuation Stairs under Fire Scenarios”, Scientific Reports, Vol. 13, Article No 16933 (2023), https://doi.org/10.1038/s41598-023-43784-6.

8. N. Okada, Y. Hasemi and S. Moriyama, “Feasibility of Upward Evacuation by Escalator—An Experimental Study”, Fire and Materials, Vol. 36, No. 5-6, pp. 429-440 (2012), https://doi.org/10.1002/fam.1118.
crossref
9. H. Kadokura, A. Sekizawa and W. Takahashi, “Study on Availability and Issues of Evacuation Using Stopped Escalators in a Subway Station”, Fire and Materials, Vol. 36, No. 5-6, pp. 416-428 (2012), https://doi.org/10.1002/fam.1097.
crossref
10. H. Ma, H. B. Zhang and H. J. Zhu, “Study on Multi-channel Coupling Evacuation Strategy of Stairs, Escalators and Elevators in Commercial Complex”, Journal of Safety Science and Technology, Vol. 17, pp. 149-154 No. 2021.

11. W. K. Chow, “A Retrospective Survey on Elevator Evacuation of Supertall Building Under Fires”, Journal of Applied Fire Science, Vol. 16, No. 4, pp. 315-327 (2006-2007), https://doi.org/10.2190/AF.16.4.c.
crossref
12. S. H. Lee and L. Ning, “A Study on the Buying Behavior Pattern by Escalator Type of Multi-complex Commercial Buildings”, Journal of the Architectural Institute of Korea Planning & Design, Vol. 33, No. 2, pp. 3-12 (2017), https://doi.org/10.5659/JAIK_PD.2017.33.2.3.
crossref
13. D. T. Greenberg and S. C. Sherman, “Escalator Injuries”, The Journal of Emergency Medicine, Vol. 28, No. 1, pp. 75-76 (2005), https://doi.org/10.1016/j.jemermed.2004.04.020.
crossref pmid
14. L. H. Schminke, V. Jeger, D. S. Evangelopoulos, H. Zimmerman and A. K. Exadaktylos, “Riding the Escalator: How Dangerous Is It Really?” Western Journal of Emergency Medicine, Vol. 14, No. 2, pp. 141-145 (2013), https://doi.org/10.5811/westjem.2012.12.13346.
crossref pmid pmc
15. J. L. Guimond, A. Henken-Siefken and A. McCague, “Escalating Risks: Injury Patterns in Escalator-related Trauma”, Cureus, Vol. 16, No. 11, Article No. e74535 (2024), https://doi.org/10.7759/cureus.74535.
crossref
16. R. J. Foster, C. N. Maganaris, N. D. Reeves and J. G. Buckley, “Centre of Mass Control is Reduced in Older People When Descending Stairs at an Increased Riser Height”, Gait Posture, Vol. 73, pp. 305-314 (2019), https://doi.org/10.1016/j.gaitpost.2019.08.004.
crossref pmid
17. O. N. Jeong, Y. S. Yun and O. H. Kwon, “Accident Prevention for the Elevator and Escalator by the Accident Type Analysis”, Journal of the Korean Society of Safety, Vol. 31, No. 4, pp. 15-21 (2016), https://doi.org/10.14346/JKOSOS.2016.31.4.15.
crossref
18. N. Kuangye, F. Shuangchang, O. Huiqing and X. JiAi, “The Influence of the Inspection and Replacement Technology of the Step and Its Related Components on the Safe Operation of Escalator”, Proceedings of the 2nd International Conference on Big Data, Artificial Intelligence and Internet of Things Engineering (ICBAIE), IEEE, pp. 1059-1062 (2021), https://doi.org/10.1109/ICBAIE52039.2021.9389966.
crossref
19. J. O. Kim, G. J. Jeong, E. I. Son, D. M. Jo, M. S. Kim, D. H. Chun, Y. M. Kim and U. C. Ryu, “Bactericidal Effect of a 275-nm UV-C LED Sterilizer for Escalator Handrails: Optimization of Optical Structure and Evaluation of Sterilization of Six Bacterial Strains”, Current Optics and Photonics, Vol. 6, No. 2, pp. 202-211 (2022), https://doi.org/10.3807/COPP.2022.6.2.202.
crossref
20. R. Leonard, S. R. O’Connor, J. Hanratty, C. Keenan, Y. Chi, J. Ferguson, A. Axiaq, A. Volz and et al, “Psychological and Psychosocial Determinants of COVID-related Handwashing Behaviours: A Systematic Review”, Campbell Systematic Reviews, Vol. 20, No. 3, Article No. e1421 (2024), https://doi.org/10.1002/cl2.1421.
crossref
21. T. Gong, J. H. Chang, J. G. Kim, S. Kang and D. Kim, “Enjoy the Silence: Noise Control with Smartphones”, Proceedings of the 26th International Conference on Computer Communication and Networks (ICCCN), pp. 1-9 (2017), https://doi.org/10.1109/ICCCN.2017.8038410.
crossref
22. Ministry of Legislation. “Operational Regulations on Safe Operation and Management of Elevators. Article 18”, National Statute Information Center (2025).

23. Z. Wang, Y. Pang, M. Gan, M. Skitmor and F. Li, “Escalator Accident Mechanism Analysis and Injury Prediction Approaches in Heavy Capacity Metro Rail Transit Stations”, Safety Science, Vol. 154, Article No 105850 (2022), https://doi.org/10.1016/j.ssci.2022.105850.
crossref
24. I. Y. Jeong, S. J. Bae, B. S. Lee, C. J. Park and S. S. Kim, “Research on Characteristics of Escalator User in Urban Railway”, The Journal of the Fall Conference of the Korean Railway Society, pp. 1556-1561 (2012).

25. ASME. “A17.1.2013/ CSA B44-13 Safety Code for Elevators and Escalators”, American Society of Mechanical Engineers (2013).

26. CEN. EN 115:1995, Safety Rules for the Construction and Installation of Escalators and Passenger Conveyors, (1995).

27. Ministry of Public Administration and Security. Escalator Safety Standards”, Notice No. 2019-32 (enforced April 4, 2019), (2020).

28. Ministry of Land, Infrastructure and Transport. Rules on Standards for Evacuation and Fire Prevention Structures, etc. of Buildings, Ordinance No 1384, August 26, (2024), (enforced December 19, 2024) (2024).

29. J. H. Choi, E. R. Galea and W. H. Hong, “Individual Stair Ascent and Descent Walk Speeds Measured in a Korean High-rise Building”, Fire Technology, Vol. 50, pp. 267-295 (2014), https://doi.org/10.1007/s10694-013-0371-4.
crossref
30. F. G. Benedict and H. S. Parmenter, “The Energy Metabolism of Women While Ascending or Descending Stairs”, American Journal of Physiology-Legacy Content, Vol. 84, No. 3, pp. 675-698 (1928), https://doi.org/10.1152/ajplegacy.1928.84.3.675.
crossref
31. H. Frantzich, Study of Movement on Stairs During Evacuation Using Video Analysing Techniques, Department of Fire Safety Engineering and Systems Safety, Lunds Universitet, Report 3079, Available From: https://portal.research.lu.se/files/4884232/1895214.pdf (1996).

32. M. Haghani, M. Sarvi, Z. Shahhoseini and M. Boltes, “Dynamics of Social Groups’ Decision-making in Evacuations”, Transportation Research Part C: Emerging Technologies, Vol. 104, pp. 135-157 (2019), https://doi.org/10.1016/j.trc.2019.04.029.
crossref
33. M. Delin, J. Norén, E. Ronchi, K. Kuklane, A. Halder and K. Fridolf, “Ascending Stair Evacuation: Walking Speed as a Function of Height”, Fire and Materials, Vol. 41, No. 5, pp. 514-534 (2017), https://doi.org/10.1002/fam.2410.
crossref
34. Y. Ma, L. Li, H. Zhang and T. Chen, “Experimental Study on Small Group Behavior and Crowd Dynamics in a Tall Office Building Evacuation”, Physica A Statistical Mechanics and its Applications, Vol. 473, pp. 488-500 (2017), https://doi.org/10.1016/j.physa.2017.01.032.
crossref
35. L. Fu, S. Cao, Y. Shi, S. Chen, P. Yang and J. Fang, “Walking Behavior of Pedestrian Social Groups on Stairs: A Field Study”, Safety Science, Vol. 117, pp. 447-457 (2019), https://doi.org/10.1016/j.ssci.2019.04.048.
crossref
36. W. Xie, E. W. M. Lee, Y. Cheng, M. Shi, R. Cao and Y. Zhang, “Evacuation Performance of Individuals and Social Groups under Different Visibility Conditions: Experiments and Surveys”, International Journal of Disaster Risk Reduction, Vol. 47, Article No 101527 (2020), https://doi.org/10.1016/j.ijdrr.2020.101527.
crossref pmid pmc
37. P. Wu, Y. Wang, J. Jiang, J. Wang and R. Zhou, “Evacuation Optimization of a Typical Multi-exit Subway Station: Overall Partition and Local Railing”, Simulation Modelling Practice and Theory, Vol. 115, Article No 102425 (2022), https://doi.org/10.1016/j.simpat.2021.102425.
crossref
38. Y. He, Q. Shi, L. Fu, Q. Chen, C. Shen, Y. Zhang, Y. Shi and J. T. Y. Lo, “Application of the Multi-grid Modelling Method to Pedestrian Social Group Dynamics Through a Bottleneck”, Simulation Modelling Practice and Theory, Vol. 139, Article No 103049 (2025), https://doi.org/10.1016/j.simpat.2024.103049.
crossref
39. Y. Ding, L. Yang, F. Weng, Z. Fu and P. Rao, “Investigation of Combined Stairs Elevators Evacuation Strategies for High Rise Buildings Based on Simulation”, Simulation Modelling Practice and Theory, Vol. 53, pp. 60-73 (2015), https://doi.org/10.1016/j.simpat.2015.01.004.
crossref
40. Y. Zang, Q. Mei and S. Liu, “Evacuation Simulation of a High-rise Teaching Building Considering the Influence of Obstacles”, Simulation Modelling Practice and Theory, Vol. 112, Article No 102354 (2021), https://doi.org/10.1016/j.simpat.2021.102354.
crossref
41. X. Li, R. Chen, Y. Zhu and C. Y. Jim, “Emergency Fire Evacuation Simulation of Underground Commercial Street”, Simulation Modelling Practice and Theory, Vol. 134, Article No 102929 (2024), https://doi.org/10.1016/j.simpat.2024.102929.
crossref
42. Y. Zhou, M. Zhong, Z. Li, X. Xu, F. Hua and R. Pan, “Simulation-based Adaptive Optimization for Passenger Flow Control Measures at Metro Stations”, Simulation Modelling Practice and Theory, Vol. 138, Article No 103021 (2025), https://doi.org/10.1016/j.simpat.2024.103021.
crossref
43. S. L. Poon, “A Dynamic Approach to ASET/RSET Assessment in Performance Based Design”, Procedia Engineering, Vol. 71, pp. 173-181 (2014), https://doi.org/10.1016/j.proeng.2014.04.025.
crossref
44. M. Appel, N. Krisch, J. P. Stein and S. Weber, “Smartphone Zombies! Pedestrians’ Distracted Walking as a Function of Their Fear of Missing Out”, Journal of Environmental Psychology, Vol. 63, pp. 130-133 (2019), https://doi.org/10.1016/j.jenvp.2019.04.003.
crossref
45. S. G. Kwon, J. S. Kim and C. E. Kim, “A Study on a Plan to Analyze Risk Factors and Secure Safety Through Analysis of Escalator Safety Accidents”, Journal of the Korea Safety Management & Science, Vol. 14, No. 2, pp. 55-63 (2012), https://doi.org/10.12812/ksms.2012.14.2.055.
crossref
TOOLS
Share :
Facebook Twitter Linked In Google+ Line it
METRICS Graph View
  • 0 Crossref
  •    
  • 1,019 View
  • 20 Download
Related articles in Int J Fire Sci Eng.

Risk Assessment of a MLCC Plant through Fire and Evacuation Simulations2021 April;35(2)



ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
AUTHOR INFORMATION
Editorial Office
Room 906, The Korea Science Technology Center The first building, 22, Teheran-ro 7 Gil, Gangnam-gu, Seoul, Republic of Korea
Tel: +82-2-555-2450/+82-2-555-2452    Fax: +82-2-3453-5855    E-mail: kifse@hanmail.net                

Copyright © 2026 by Korean Institute of Fire Science and Engineering.

Developed in M2PI

Close layer
prev next